Common faults and solutions of gates

2020-08-14
1. Possible reasons why the railings of the gates of the campus access control are lower than the horizontal position
a.The lower limit switch screw of the control drop lever is loose.
b. The railing is too heavy.
c. The worm gear of the motor is worn out, which causes the self-locking of the motor to deteriorate, and the machine has an impact limit.
d. The controller moves slowly, causing the machine to have a limit
e. The arm connected with the connecting rod rotates relative to the axis three

Solutions to the corresponding solutions for the barriers of the gates in the gates of the campus access control that are lower than the horizontal position
a. After re-adjusting the lower limit, tighten the lower limit screw.
b. Increase the spring
c. Replace the motor.
d. Replace the controller
e. Re-adjust the machine and tighten the screws on the arm



2. Possible reasons why the railing of the gates of the campus access control gate is higher than the horizontal position
a.The lower limit switch screw of the control drop lever is loose.
b. The railing is shortened.
c. The arm connected with the connecting rod rotates relative to the axis three

Solutions to the corresponding solutions for the barriers of the gates of the campus entrance control passage when the barrier is higher than the horizontal position
a. After re-adjusting the lower limit, tighten the lower limit screw.
b. Reduce the tension spring, while fine-tuning the adjustment screw sleeve
c. Re-adjust the machine and tighten the screws on the arm



3. Possible reasons why the railing of the gates of the campus access control gate is less than 90 degrees from the ground
a.The upper limit switch screw of the control lever is loose.
b. The arm connected with the connecting rod rotates relative to the axis three

The solution to the problem that the railing of the gate of the access control channel is less than 90 degrees to the ground
a. After re-adjusting the upper limit, tighten the lower limit screw.
b. Re-adjust the machine and tighten the screws on the arm



4. Possible reasons why the railing and the ground are greater than 90°
a.The upper limit switch screw of the control lever is loose.
b. The arm connected with the connecting rod rotates relative to the axis three
c. The worm gear of the motor is worn out, which causes the self-locking of the motor to deteriorate, and the machine has an impact limit.
d. The controller moves slowly, causing the machine to have a limit

Solution to the corresponding solution of the railing of the gates of the access control passage and the ground is greater than 90 degrees
a. After re-adjusting the upper limit, tighten the lower limit screw.
b. Re-adjust the machine and tighten the screws on the arm
c. Replace the motor.
d. Replace the controller.



5. Possible reasons why the gate motor can rotate but the railing does not move
a. The motor worm wheel is completely worn
b. Free relative rotation between the arm and the axis three

The gate motor can rotate but the railing does not move. The corresponding solution
a. Replace the motor.
b. Re-adjust the machine and tighten the screws on the arm



6. Possible reasons for the motor of the gate of the access control channel to stop at the limit
a.The lower limit switch screw of the control drop lever is loose.
b. Reed switch limit switch fails and opens
c. The worm gear of the motor is worn out, causing the self-locking performance of the motor to deteriorate.
d. Controller action speed is slow (slow access control channel gate is available)
e. Turn on the clutch device when the machine is in the drop position without railing

Corresponding solutions to the blocking of the gate motor of the access control channel
a. After re-adjusting the lower limit, tighten the lower limit screw.
b. Replace the positioning plate (for the double dry reed switch, just turn off the invalid limit switch and turn on another backup limit switch)
c. Replace the motor.
d. Replace the controller (for fast access gates)
e. When the railing is not installed, to open the clutch device, make sure that the machine is in the starting position

Note: When the main unit of the access control channel is parked in the drop position without a railing, it is strictly forbidden to open the clutch device. All the main unit of the access control channel that is stuck at the limit must be knocked on the clutch handle with a heavy object and twisted by hand. Move the clutch device until the motor can rotate, and then solve the problem according to the above method



7. Possible reasons why the motor of the gate of the access control channel is not stuck, but the button motor cannot move
a. Reed switch limit switch fails and short circuit occurs
b. Wiring terminals are loose and power off
c. The railing is long and heavy, but there are few tension springs (dropping position)
d. The machine is not equipped with a tension spring (starting the motor at the position of the rod)
e. The capacitor is damaged (use a multimeter to detect)
f. Insufficient motor power

The gate motor of the access control channel is not stuck, but the button motor cannot move. The corresponding solution
a. Replace the positioning plate (for a double reed switch, just turn off the invalid limit switch and turn on another spare limit switch)
b. Check the connection of each terminal to ensure that the terminals are in good contact.
c. Increase tension spring or thicken tension spring
d. According to the railing length, install the corresponding tension spring
e. Replace the capacitor.
f. Replace the motor

Shenzhen Maintex Intelligent Control Co., Ltd.
Business Type:Manufacturer
Product Range:DC Motor , AC Motor , Stepper Motor
Products/Service:Stepper Motor , Brushless motor , Dc motor , treadmill used motor , Brushed Dc Motor , Fuji motor
Certificate:ISO14001 , ISO/TS16949 , ISO9001 , RoHS
Company Address:Zhengde Science Park, No. 8, Pingdi Street, Longgang District, Shenzhen, Guangdong, China

Previous: Application case of smart toilet motor on smart toilet

Next: What should I pay attention to when purchasing a remote control aircraft brushless DC motor?